Oil Solutions
• With FluidTech’s unique modular build configuration the flushing unit is capable of 220lpm flushing unit “Self contained”

• Add on tank will allow up 1400 litres of volume, the flushing tank is equipped with heating elements and a heat exchanger to maintain a constant flushing

• Add on high flow/high velocity piston motor/ triple gear pump transfer station allowing an achievable 1320 lpm

• This high flow flushing unit will allow FluidTech to flush your pipes at the required Reynolds number

• Nr = (3160 x GPM “US”) / (CS X D “inches”) = Reynolds #, general rule of thumb is this Reynolds number should be above 4000Nr